Electromagnetic clutch use will encounter problems

2021-12-03 01:41:06
second

Although the electromagnetic clutch itself has a simple structure and convenient device protection, in the application process, due to various factors, the electromagnetic clutch will have different problems, such as:


1. Can not start, input electromagnetic clutch voltage may be too low, the conventional input voltage is DC24V.


2. Dynamic instability. Skidding may be too hot.


3. The voltage is unstable.


4 coil short circuit, encountered this problem is usually replaced or repaired, promote the replacement or modification of the electromagnetic clutch circuit.


The operation is unstable, it is likely that the input voltage is unstable, the power of the detected power supply is about 1.5 times greater than the rated power of the electromagnetic clutch, and the voltage is shaken in the planning of +-5%. The way to deal with the unstable operation is to check the voltage state and stabilize the voltage. Another situation is that the conflict heats up, because the heat can cause the coil to burn out or short.